PRODUCT OVERVIEW

GYXTW fiber cable is self-supported outdoor cable designed for aerial network construction and underground cable ducting. The structure of GYFXY cable is covering singlemode or multimode fibers into HDPE sheath, there are full of compound gel inside cable against water. Loose tube and water-proof gel make sure fiber’s tight and water-resistance performance. There are 2 parallel steel wires at PE sheath as strengthen member to guarantee cable’s tensile and pulling strength.

What’s more, GYXTW cable’s accurate fiber excess length control provides good cable tensile performance. Loose tube material equips water-proof and high tensile characteristics, compound filling gel protects fibers well at loose tube. PE sheath equips good performance against ultraviolet ray. Cable adopt bellowing measures to guarantee water-proof performance: single steel wire strengthen member, special compound water-proof filling gel at loose tube, full fibers counts and ALP cover aluminum strip provides moisture-proof performance.

PRODUCT DETAILS

  • Meet YD/T 901-2001as and IEC 60794-1 standard
  •  Good mechanical and ductility performance at cold weather
  •  Solid HDPE sheath equips water-proof and anti-mouse bite function
  •  Corning G652D or G657A1 or multimode fiber for chosen
  •  Compact cable structure against any shake at transportation and damage
  •  Strong metallic central strength member
  •  Full lubrication gel filling fiber bunch
  • Moisture-proof, Bulletproof and water-proof

    Main Mechanical and Environmental Performances

    Item Test Standard Specified Value Requirements
    Tension IEC 60794-1-2-E1 See Technical data Additional attenuation:      ≤0.1dB after test
    Crush IEC 60794-1-2-3 See Technical data Additional attenuation:      ≤0.1dB after test
    Impact IEC 60794-1-2-4 R=300mm,10Nm          in 3 different places Additional attenuation:      ≤0.1dB after test
    Repeated Bending IEC 60794-1-2E6 R=20*D Additional attenuation:      ≤0.1dB after test
    Water  Penetration IEC 60794-1 -2-3 Sample length=3m           Water height=1 m        24 hours No water leakage
    Temperature Cycling IEC 60794-1-2-F1 -20℃-+75℃ Attenuation change:            ≤0.05dB after test

GYXTW Cable Mechanical Parameters

Fiber Count Nominal Diameter(mm) Nominal Weight (kg/km) Max Fibers per Bunch Numbers of Bunches & Fillers Min Tensile Load(N) Max Tensile Load(N) Min Crush Resistance (N) Min Crush Resistance (N)
2 to 30 9.7 90 6 5 1500 600 1000 600
32 to 36 10.3 109 6 6 1500 600 1000 600
38 to 60 10.8 119 6 5 1500 600 1000 600
62 to 72 11.5 145 12 6 1500 600 1000 600
74 to 96 13.5 175 12 8 1700 600 1000 600
98 to 120 14.8 209 12 10 2000 600 1000 600
122 to 144 16.6 249 12 12 2000 600 1000 600
146 to 216 17.8 254 12 18 2000 600 1000 600
218 to 288 19 325 12 24 2000 600 1000 600

Optical Fiber Performance

Fiber style Unit SM G652D MM 50/125 MM 62.5/125
Condition mm 1310/1550 850/1300 850/1300
Attenuation dB/km ≤0.36/0.22 ≤3.0/1.0 ≤3.0/1.0
Cladding diameter um 125±1 125±1 125±1
Cladding non-circularity % ≤1.0 ≤1.0 ≤1.0
Coating diameter um 242±7 242±7 242±7